Registering a new trial?

To achieve prospective registration, we recommend submitting your trial for registration at the same time as ethics submission.

The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this information for consumers
Trial registered on ANZCTR


Registration number
ACTRN12623000255684
Ethics application status
Approved
Date submitted
21/02/2023
Date registered
9/03/2023
Date last updated
9/03/2023
Date data sharing statement initially provided
9/03/2023
Type of registration
Prospectively registered

Titles & IDs
Public title
Reliability of knee-extensor strap stabilisation
Scientific title
A reliability study in Inclusion Body Myositis (IBM) to evaluate knee extensor strength using a stabilisation strap
Secondary ID [1] 308665 0
Nil known
Universal Trial Number (UTN)
Trial acronym
Linked study record

Health condition
Health condition(s) or problem(s) studied:
Inclusion Body Myositis 328587 0
Condition category
Condition code
Neurological 325604 325604 0 0
Other neurological disorders
Musculoskeletal 326166 326166 0 0
Other muscular and skeletal disorders

Intervention/exposure
Study type
Interventional
Description of intervention(s) / exposure
All interventions will be delivered during a single study visit at the study site, Murdoch University. This study visit will take approximately 2 hours.

All participants will undergo identical initial stages during which they will be asked to provide written informed consent, undergo screening, and provide demographic data.

All participants will then have knee-extensor strength assessed using the clinical reference standard, the Humac Norm.

Knee-extensor strength will then be assessed using the measurement methods being compared. Arm 1 will be assessed first using the Strap Stabilised Handheld Dynamometry (SSHD) and then the Operator Stabillised Handheld Dynamometry (SSHD), while Arm 2 will be assessed in the reverse order: first using the OSHD and then the SSHD.

Interventions are as follows with approximate time frames. Note that the order of OSHD and SSHD will vary.

1. Written informed consent and collection of demographic data (deidentified data including initials, sex, birth month and year), including medical information related to IBM diagnosis, duration of disease and use of mobility aids. (Approx. 20 mins)
2. Isokinetic dynamometer (Humac Norm) testing (Approx. 20 mins, including 10 mins rest prior)
3. Operator-stabilised handheld dynamometer (OSHD) utilising Citec hand-held precision digital force gauge CT 3002/30 (Approx. 15 mins, including 10 mins rest prior)
4. Strap-stabilised handheld dynamometer (SSHD) (Approx. 15 mins, including 10 mins rest prior)

The participant will have an opportunity to have some light refreshments and rest before leaving the unit.

Further information is provided on the Strap-Stabilised Handheld Dynamometry (SSHD) and Operator Stabilised Handheld Dynamometry (OSHD):

Operator-stabilised handheld dynamometer (OSHD)
Also known as a handheld dynamometer, this is the standard currently in use for objective muscle strength testing in clinical practice settings. These are portable, handheld devices capable of assessing various muscle groups. The participant performs a maximal effort action against the device whilst the operator holds the device stationary, resisting the action. This study will utilise the Citec hand-held precision digital force gauge CT 3002/30.

Strap-stabilised handheld dynamometer (SSHD)
The novel method being assessed in this trial. This method utilises the same handheld dynamometer as described above. Instead of the operator stabilising the device, a strap is used to stabilise the device. The strap is attached to the handheld dynamometer and then fixed to the frame of the plinth or chair where the participant is seated. This method is used specifically when assessing knee extension.


Intervention code [1] 325136 0
Diagnosis / Prognosis
Intervention code [2] 325563 0
Early detection / Screening
Intervention code [3] 325564 0
Treatment: Devices
Comparator / control treatment
All interventions will be delivered during a single study visit at the study site, Murdoch University.

Two methods of hand-held dynamometry will be assessed against the industry 'gold standard', the Humac Norm.

Isokinetic dynamometer (Humac Norm):
The Humac Norm is a computer-assisted fixed force plate machine which is considered the gold-standard measurement in muscle strength testing. It will be used as the clinical reference standard for assessment of validity of each method of handheld dynamometry. The participant is seated in a padded chair and stabilised with straps across the torso, waist, and thigh. The participant is asked to perform a maximal effort knee-extension against a padded, rigid force-plate. Study participants will be asked to perform three maximal effort knee extensions on each leg (3 x right leg, followed by 3 x left leg). Each effort will last three seconds, with 60 seconds rest in between. All efforts will be recorded in the study database. Force will be recorded in Newton-metres.

This intervention will be administered by a trained, delegated member of the study team in accordance with study standard operating procedures. The same team member will perform Humac Norm testing for all study participants to limit inter-rater variability.

At least 10 minutes of rest will be given prior to Humac Norm administration.

The Humac Norm will be the first intervention administered for all participants.
Control group
Active

Outcomes
Primary outcome [1] 333439 0
Reliability of Strap Stabilised Handheld Dynamometry (SSHD) scores of knee extensor strength, compared to reliability Operator Stabilised Handheld Dynamometry (OSHD) scores, when measured against Isokinetic knee extensor strength testing (Humac Norm) in the IBM population. This will be measured using a test-retest analysis of both methods.
Timepoint [1] 333439 0
All three measures of knee extensor strength will be collected during a single study visit (timepoint).
Secondary outcome [1] 417130 0
The validity of knee extensor strength testing using both SSHD and OSHD in the IBM population. Validity will be assessed by comparing each handheld dynamometry method against the ‘gold’ standard isokinetic dynamometer (Humac Norm).
Timepoint [1] 417130 0
All three measures of knee extensor strength will be collected during a single study visit (timepoint).

Eligibility
Key inclusion criteria
•Age at least 18 years or over
•Has a confirmed diagnosis of Inclusion Body Myositis by a neuromuscular specialist
•Able to attend the a single study visit of approximately 3 hours duration during the study period
•Able to provide written informed consent for the study
•Able to independently and safely transfer on and off the Humac Norm
•Knee extensor modified Medical Research Council grade of at least 4- in one or both legs as assessed within the past 6 months.
Minimum age
18 Years
Maximum age
No limit
Sex
Both males and females
Can healthy volunteers participate?
No
Key exclusion criteria
•Recent history (within six months) of fracture or pathology affecting the knee joint that would reasonably cause pain or discomfort or prevent the participant from performing a resisted knee extension.
•Any condition precluding the participant from performing any part of the study procedures.
•Any clinical assessment by the Sponsor-Investigator that the participant is unable or unsafe to take part in the study.

Study design
Purpose of the study
Treatment
Allocation to intervention
Randomised controlled trial
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Sequence allocation is revealed on registration of the participant on the study database following receipt of informed consent.
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Participants will be randomly allocated to one of two sequences of testing for the handheld dynamometry testing. Participants will either undergo testing with a SSHD followed by OSHD, or vice versa. The allocation of participants to each sequence will be determined by block randomisation. A study team member not directly involved in intervention measurement or analysis of the study results will prepare the randomisation schedule to maintain balance between study arms.
Masking / blinding
Open (masking not used)
Who is / are masked / blinded?



Intervention assignment
Crossover
Other design features
Phase
Not Applicable
Type of endpoint/s
Efficacy
Statistical methods / analysis
Sample Size Calculation Methods
The target sample size for this study will be 30 participants.

Based on the data (r=.86) from Bohannon et al (2011) along with the assumption that greater variance may be observed amongst our clinical cohort, we have opted to employ a correlation of 0.8 (with an upper critical r of .74; using correlation of p H0=0.5) for our sample size analysis. Using a two-tailed analysis, with the alpha error probability set at 0.05 and a power of 0.8, we require a minimum sample size of N=29.

The publicly available software, G*Power (version 3.1) was used for this power calculation.


Data Analysis Methods

Baseline Descriptive Statistics
The distributions of demographic and clinical characteristics will be described for the overall cohort using standard summary statistics

Analysis of Fatiguability
An independent sample t-test will be run to compare intra-device variability for the SSHD and OSHD between crossover arms. This assessment will provide an understanding of whether further statistical adjustment is required to account for potential participant fatigue affecting the third method of measurement compared to the second.

Analysis of the Primary Outcome
Test-retest reliability will be assessed for both the OSHD and the SSHD by calculating a bivariate Pearson correlation coefficient (r) and corresponding p-values for intra-participant efforts on each method. If p<.5 and r>.7 the test will be deemed reliable. If p>.5 or r<.7 then researchers do not have evidence of test-retest reliability.

Prior to calculating r, the assumptions of normality, linearity and homoscedasticity will be assessed.

An Intraclass Correlation Coefficient (ICC) will also be generated to assess test-retest reliability. The ICC will be generated using a single measurement, absolute agreement, 2-way mixed-effects model. This will be reported as an ICC and a 95% confidence interval. The ICC will be interpreted using the ranges suggested by Koo & Li (2016).

Secondary Outcome
Two statistical analyses will be performed to assess validity of the SSHD and OSHD: a Pearson correlation coefficient and a Bland-Altman plot.

A bivariate Pearson’s product-moment correlation coefficient (r) will be calculated for both the SSHD and the OSHD (against the isokinetic dynamometer) to assess for the direction and strength of the relationship of each handheld dynamometry method with the ‘gold’-standard.

Bland-Altman plots will be used to assess agreement of each of the handheld dynamometer methods (the SSHD and OSHD) against the ‘gold’ standard.

Two Bland-Altman plots will be generated: one comparing the SSHD with the isokinetic dynamometer and one comparing the OSHD with the isokinetic dynamometer. The assumption of normal distribution will first be assessed. The participant’s mean muscle force measurement (in Newton-meters) for each method will be used for these calculations. The limits of agreement will be assessed as a 95% confidence interval.


References
Bohannon RW, Bubela DJ, Wang Y, Magasi SR, Gershon RC. Adequacy of Belt-Stabilized Testing of Knee Extension Strength. J Strength Cond Res. 2011;25(7):1963-1967. doi: 10.1519/JSC.0b013e3181e4f5ce

Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15:155-163. doi: 10.1016/j.jcm.2016.02.012

Recruitment
Recruitment status
Not yet recruiting
Date of first participant enrolment
Anticipated
Actual
Date of last participant enrolment
Anticipated
Actual
Date of last data collection
Anticipated
Actual
Sample size
Target
Accrual to date
Final
Recruitment in Australia
Recruitment state(s)
WA
Recruitment hospital [1] 23753 0
Perron Institute for Neurological and Translational Science - Nedlands
Recruitment postcode(s) [1] 39198 0
6009 - Nedlands

Funding & Sponsors
Funding source category [1] 312900 0
University
Name [1] 312900 0
Murdoch University
Country [1] 312900 0
Australia
Primary sponsor type
University
Name
Murdoch University
Address
90 South St, Murdoch WA 6150
Country
Australia
Secondary sponsor category [1] 314578 0
None
Name [1] 314578 0
Address [1] 314578 0
Country [1] 314578 0
Other collaborator category [1] 282513 0
University
Name [1] 282513 0
University of Notre Dame Australia
Address [1] 282513 0
32 Mouat St, Fremantle WA 6160
Country [1] 282513 0
Australia

Ethics approval
Ethics application status
Approved
Ethics committee name [1] 312174 0
Murdoch University Human Research Ethics Committee
Ethics committee address [1] 312174 0
Murdoch University
Chancellery Building Room 1.006
South Street, Murdoch
Western Australia 6150
Ethics committee country [1] 312174 0
Australia
Date submitted for ethics approval [1] 312174 0
20/01/2023
Approval date [1] 312174 0
01/03/2023
Ethics approval number [1] 312174 0
2023/013

Summary
Brief summary
Inclusion Body Myositis (IBM) is the most common inflammatory muscle disease affecting people aged over 50. Weakness of knee-extensors is characteristic of IBM and knee-extensor strength is frequently used as a key outcome measure to track disease progression and response to interventions in clinical practice and clinical trials. Currently, there exists ambiguity over the best and most practical measurement tool for this purpose.

The aim of this study is to assess and compare two methods of portable dynamometry that each measure knee-extensor strength in IBM patients. One of these methods, operator-stabilised handheld dynamometry (OSHD), is the current clinical standard for objective assessment of knee extensor strength in IBM, however this method can be influenced by limb position and operator strength. The second method, strap-stabilised handheld dynamometry (SSHD) addresses the shortcomings of OSHD by utilising a stabilisation strap to hold the handheld dynamometer in place.

A crossover design for testing sequence will be used to assess reliability of SSHD as compared to OSHD for knee-extensor testing. Validity of both methods will also be assessed by comparing both OSHD and SSHD to the clinical reference (‘gold’) standard, an isokinetic dynamometer. This design has been chosen to collect data that will enable assessment of both reliability and validity of these methods using the participant as a control. It will enable the comparison of the use of SSHD in this population as compared to OSHD and constitutes a pivotal study in the assessment of this method of dynamometry.

All participants will be asked to present for a single testing visit (approximately 3 hours duration), at which eligibility screening will be conducted, written informed consent will be received, and testing will occur. There are no follow-up measures or interventions.

Participants are only required to attend the single testing session, which minimises burden on participants and maximises study accessibility. Participants will be randomly allocated to one of two study visit sequences, which differ in the order of testing of OSHD and SSHD.
Trial website
Trial related presentations / publications
Public notes

Contacts
Principal investigator
Name 123734 0
Prof Merrilee Needham
Address 123734 0
Murdoch University
90 South Street
Murdoch
WA 6150
Country 123734 0
Australia
Phone 123734 0
+610893601334
Fax 123734 0
+610893601680
Email 123734 0
Contact person for public queries
Name 123735 0
Kelly Beer
Address 123735 0
Murdoch University
90 South Street
Murdoch WA 6150
Country 123735 0
Australia
Phone 123735 0
+610893601365
Fax 123735 0
+610893601680
Email 123735 0
Contact person for scientific queries
Name 123736 0
Kelly Beer
Address 123736 0
Murdoch University
90 South Street
Murdoch WA 6150
Country 123736 0
Australia
Phone 123736 0
+610893601365
Fax 123736 0
+610893601680
Email 123736 0

Data sharing statement
Will individual participant data (IPD) for this trial be available (including data dictionaries)?
Yes
What data in particular will be shared?
Individual participant data that underlie the results reported in this article after de-identification (text, tables, figures and appendices)
Study protocol, PICF, study specific Standard Operating Procedures
When will data be available (start and end dates)?
Beginning 6 months following analysis and subsequent publication of the study; no end date determined
Available to whom?
Researchers from a recognised research institution whose proposed use of the data has been ethically reviewed and approved by an independent committee and who accept the Sponsoring Institutions’ conditions for access.
Available for what types of analyses?
Any purpose
How or where can data be obtained?
Access subject to approval by Principal Investigator. The Principal Investigator can be contacted via the Clinical Research Manager, Kelly Beer:

[email protected]


What supporting documents are/will be available?

Doc. No.TypeCitationLinkEmailOther DetailsAttachment
18097Study protocol    Will be published once approved by ethics and also... [More Details]
18098Informed consent form    Will be available via email request to the study t... [More Details]
18099Ethical approval    Will be available via email request to the study t... [More Details]



Results publications and other study-related documents

Documents added manually
No documents have been uploaded by study researchers.

Documents added automatically
No additional documents have been identified.